1. Cek Detail Config di Interface ke arah ONT
OLT-ZTE_C320#show run interface gpon-onu_1/2/5:4
Building configuration…
!
interface gpon-onu_1/2/5:4
name Customer-1
description Internet-Customer-1
tcont 1 name acsata profile UP-50M
gemport 1 name Internet unicast tcont 1 dir both
gemport 1 traffic-limit upstream DOWN-50M downstream DOWN-50M
switchport mode hybrid vport 1
service-port 1 vport 1 user-vlan 1247 vlan 1247 svlan 1402
!
end
OLT-ZTE_C320#show run interface gpon-onu_1/2/5:5
Building configuration…
!
interface gpon-onu_1/2/5:5
name Customer-2
description Internet-Customer-2
tcont 1 name acsata profile UP-60M
tcont 1 gap mode2
gemport 1 name Internet unicast tcont 1 dir both
gemport 1 traffic-limit upstream DOWN-60M downstream DOWN-60M
switchport mode hybrid vport 1
service-port 1 vport 1 user-vlan 1245 vlan 1245 svlan 1402
!
end
2. Cek Status Interface ONT
OLT-ZTE_C320#show gpon onu state gpon-olt_1/2/5 4
OnuIndex Admin State OMCC State O7 State Phase State
—————————————————————————-
gpon-onu_1/2/5:4 enable disable unknown LOS <—– Tanda Link Down
ONU Number: 0/1
OLT_ZTE_C320#show gpon onu state gpon-olt_1/2/5 5
OnuIndex Admin State OMCC State O7 State Phase State
—————————————————————————-
gpon-onu_1/2/5:5 enable enable operation working <—– Tanda Link UP
ONU Number: 1/1
3. Cek Nilai Optik ONT
OLT-ZTE_C320#show pon power attenuation gpon-onu_1/2/5:4
OLT ONU Attenuation————————————————————————– up Rx :no signal Tx:N/A N/A down Tx :4.200(dbm) Rx:N/A N/A
OLT-ZTE_C320#show pon power attenuation gpon-onu_1/2/5:5
OLT ONU Attenuation————————————————————————– up Rx :-20.850(dbm) Tx:2.868(dbm) 23.718(dB) down Tx :4.230(dbm) Rx:-18.210(dbm) 22.440(dB)
4. Cek Utilisasi Bandwith Link ONT Real Time
OLT-ZTE_C320#show interface gpon-onu_1/2/5:4
ONU statistic: Input rate : 1471 Bps 12 pps Output rate: 2212 Bps 13 pps Input bandwidth throughput :0.0% Output bandwidth throughput: N/A
OLT-ZTE_C320#show interface gpon-onu_1/2/5:5
ONU statistic: Input rate : 1411 Bps 9 pps Output rate: 1423 Bps 9 pps Input bandwidth throughput :0.0% Output bandwidth throughput: N/A
5. Cek ONT Uptime dan History:
OLT-ZTE_C320#show gpon onu detail-info gpon-onu_1/2/5:5
ONU interface: gpon-onu_1/2/5:5 Name: Customer-2 Type: ZTEG-F660 State: ready Admin state: enable Phase state: working Authentication mode: sn SN Bind: enable with SN check Serial number: ZTEGC1192DD7 Password: Device ID: Description: Internet-Customer-2 Vport mode: gemport DBA Mode: Hybrid ONU Status: enable OMCI BW Profile: enable Line Profile: N/A Service Profile: N/A Alarm Profile: N/A Performance Profile: N/A ONU Distance: 3540m Online Duration: 10h 42m 07s FEC: none—————————————— Authpass Time OfflineTime Cause 1 2018-07-28 04:49:02 2018-07-28 04:49:02 LOS 2 2018-07-28 05:08:31 2018-07-28 05:08:32 LOS 3 2018-07-28 05:13:42 2018-07-28 05:13:42 LOS 4 2018-07-28 05:51:33 2018-07-28 05:51:33 LOS 5 2018-07-28 07:23:11 2018-07-28 07:23:12 LOS 6 2018-07-28 08:14:14 2018-07-28 08:14:14 LOS 7 2018-07-29 11:28:39 2018-07-29 11:30:22 LOS 8 2018-07-29 11:33:33 2018-07-29 11:34:36 LOS 9 2018-07-29 11:36:01 2018-07-29 11:54:32 LOSi 10 2018-07-29 11:56:31 0000-00-00 00:00:00
6. Cek Mac Address Perangkat yang terkoneksi ke ONT
OLT-ZTE_C320#show mac gpon onu gpon-onu_1/2/5:5
Total mac address : 2
Mac address Vlan Type Port Vc————————————————————————6c3b.6b51.cc09 1402 Dynamic gpon-onu_1/2/5:5 vport 16c3b.6b61.d257 1402 Dynamic gpon-onu_1/2/5:5 vport 1
7. Cek ONT VersionOLT-ZTE_C320#show gpon remote-onu equip gpon-onu_1/2/5:5Vendor ID: ZTEG Version: V5.0 SN: ZTEGc1192dd7 Admin status: unlock Battery backup: false Security Mode: aes Product code: 0 TotalPrioQueueNum: 56 TotalTrafficSchNum: 7 TrafficMgmtOption: priority-controlled OperState: enable EquipID: F620V5.0 OMCC Version: a0 Security Capability: aesModel: F620V5.0Survival time: N/ATotalGemPortNum: 256SysUpTime: 0
8. Cek Status Port di ONT
OLT-ZTE_C320#show gpon remote-onu interface eth gpon-onu_1/2/5:5
Interface: eth_0/1Speed status: full-100Operate status:enableAdmin status: unlockArc: 0 Arc-interval 0Expect-type: 0Speed config: autoEth-loop: disableMax-frame: 1632Pause-time: 0Wiring : dceBridgeOrIP: eitherPPPOE-filter: disablePower-control: disable
9. Reboot/Restart ONT
OLT-ZTE_C320#config t
Enter configuration commands, one per line. End with CTRL/Z.
OLT-ZTE_C320(config)#pon-onu
OLT-ZTE_C320(config)#pon-onu-mng gpon-onu_1/2/5:5
OLT-ZTE_C320(gpon-onu-mng)#reboot
10. Shutdown Port 1 di ONT
OLT-ZTE_C320#config t
Enter configuration commands, one per line. End with CTRL/Z.
OLT-ZTE_C320(config)#pon-onu
OLT-ZTE_C320(config)#pon-onu-mng gpon-onu_1/2/5:5
OLT-ZTE_C320(gpon-onu-mng)#interface eth eth_0/1 state lock
11. Cek Konfigurasi PON ONU
OLT_ZTE_C320#show onu running config gpon-onu_1/2/11:8
pon-onu-mng gpon-onu_1/2/11:8
service Internet-Customer1 gemport 1 vlan 671
service OAM gemport 2 vlan 1450
service Internet-Customer2 gemport 3 vlan 1490
vlan port eth_0/1 mode tag vlan 671
vlan port eth_0/3 mode tag vlan 1490
12. Check OLT Uptime
OLT_ZTE_C320#show system-group
System Description: ZX Version V4.
Started before: 47484 days, 5 hours, 25 minutes
OLT_ZTE_C320#
13. Check OLT Board
GTGOE = 8 Port (O=Octal)
GTGH = 16 Port (H=Hexa
OLT-ZTE_C320#sho card
Rack Shelf Slot CfgType RealType Port HardVer SoftVer Status
——————————————————————————-
1 1 0 PRWG PRWG N/A INSERVICE
1 1 1 PRWG PRWG N/A INSERVICE
1 1 2 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 3 GTGH GTGHG 16 120700 V1. INSERVICE
1 1 4 GTGO GTGOE 8 110301 V1.2 INSERVICE
1 1 5 GTGO GTGOE 8 110301 V1.2 INSERVICE
1 1 6 GTGO GTGOE 8 110301 V1 INSERVICE
1 1 7 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 8 GTGO GTGOE 8 110301 V1 INSERVICE
1 1 9 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 10 SCXN SCXN N/A 120902 V1. STANDBY –> Control Module
1 1 11 SCXN SCXN N/A 120902 V1. INSERVICE –> Control Module
1 1 12 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 13 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 14 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 15 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 16 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 17 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 18 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 19 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 21 HUTQ HUTQ 4 100101 V1. INSERVICE –> Uplink Module
1 1 22 HUTQ HUTQ 4 100101 V1. INSERVICE –> Uplink Module
OLT-ZTE_C320#
14. Check OLT Processor dan Memory
OLT-ZTE_C320#show processor
Rack Shelf Slot CPU(5s) CPU(1m) CPU(5m) PhyMem(MB) Memory
——————————————————————————-
1 1 2 14% 13% 13% 256 55%
1 1 3 19% 21% 21% 1024 16%
1 1 4 14% 12% 12% 256 55%
1 1 5 10% 9% 10% 256 55%
1 1 6 11% 11% 11% 256 55%
1 1 7 9% 11% 11% 256 55%
1 1 8 11% 10% 10% 256 55%
1 1 9 10% 9% 10% 256 55%
1 1 10 1% 1% 1% 1024 26%
1 1 11 2% 1% 1% 1024 27%
1 1 12 11% 10% 10% 256 55%
1 1 13 9% 10% 10% 256 55%
1 1 14 9% 11% 11% 256 55%
1 1 15 9% 11% 11% 256 55%
1 1 16 9% 11% 11% 256 55%
1 1 17 12% 11% 11% 256 55%
1 1 18 9% 11% 11% 256 55%
1 1 19 12% 11% 11% 256 55%
1 1 21 13% 12% 12% 32 21%
1 1 22 13% 12% 12% 32 21%
OLT_ZTE#
15. Check OLT Temperature
OLT-ZTE_C320#show temperature
Card Temperature:
——————————————-
Slot Temperature(Celsius scale)
——————————————-
0 N/A.
1 N/A.
2 35
3 32
4 33
5 35
6 36
7 35
8 34
9 37
10 20
11 20
12 34
13 35
14 36
15 36
16 35
17 35
18 35
19 32
20 N/A.
21 N/A.
22 N/A.
——————————————-
OLT-ZTE_C320#
16. CHECKING OLT PER SLOT
OLT-ZTE_C320#show card slotno 12
Config-Type : GTGO Status : INSERVICE
Real-Type : GTGOE Serial-Number : 272
Port-Number : 8 BootROM-VER : V1.2.024 14:17:00
PCB-VER : 11 Software-VER : V1.2.:52:53
Cpld-VER : V1
Phy-Mem-Size : 256MB Main-CPU : PowerPC Processor
Cpu-Usage : 10% Cpu-Alarm-Threshold : 100%
Mem-Usage : 55% Mem-Alarm-Threshold : 100%
Uptime : 259 Day , 11 Hours , 16 Minutes , 57 Second
OL01#
17. FINDING ONT BY SN NUMBER
OLT-ZTE_C320#sho gpon onu by sn ABCDEFGHIJ
SearchResult
—————–
gpon-onu_1/4/1:2
OLT-ZTE_C320#
18. CHECKING ONT STATUS
OLT-ZTE_C320#sho gpon onu sta gpon-olt_1/4/1 2
OnuIndex Admin State OMCC State O7 State Phase State
—————————————————————————-
gpon-onu_1/4/1:2 enable enable operation working –> modem normal
ONU Number: 1/1
OLT-ZTE_C320#
19. CHECKING ONT UPTIME AND ONT HISTORY LOGS
OLT-ZTE_C320#sho gpon onu detail-info gpon-onu_1/4/1:2
ONU interface: gpon-onu_1/4/1:2
Name: ONU-1:2
Type: ZTEG-F660 –> ONT type 4 ports
State: ready
Admin state: enable
Phase state: working
Authentication mode: sn
SN Bind: enable with SN check
Serial number: ABCDEFGHIJ
Password:
Device ID:
Description: IRONMAN
Vport mode: gemport
DBA Mode: Hybrid
ONU Status: enable
OMCI BW Profile: enable
Line Profile: N/A
Service Profile: N/A
Alarm Profile: N/A
Performance Profile: N/A
ONU Distance: 2510m
Online Duration: 17h 28m 14s –> Online Duration
FEC: none
——————————————
Authpass Time OfflineTime Cause
1 2016-12-31 16:16:25 2017-01-04 03:34:37 DyingGasp –> ont Off
2 2017-01-04 03:35:51 2017-01-04 23:25:01 DyingGasp
3 2017-01-04 23:30:09 2017-01-05 11:08:53 DyingGasp
4 2017-01-05 11:11:17 2017-01-08 08:12:27 DyingGasp
5 2017-01-08 08:13:39 2017-01-10 10:42:57 LOS –> physical problem
6 2017-01-10 10:43:44 2017-01-11 00:25:41 DyingGasp
7 2017-01-11 00:27:11 2017-03-09 11:46:17 DyingGasp
8 2017-03-09 11:54:12 2017-03-15 18:53:03 DyingGasp
9 2017-03-15 19:28:56 2017-03-29 01:29:10 DyingGasp
10 2017-03-29 01:30:18 0000-00-00 00:00:00
OLT-ZTE_C320#
20. CHECKING ONT MAC ADDRESS
OLT-ZTE_C320#sho mac gpon onu gpon-onu_1/4/1:2
Total mac address : 2
Mac address Vlan Type Port Vc
————————————————————————
KEREN.KEREN.KEREN 212 Dynamic gpon-onu_1/4/1:2 vport 1
BEKEN.BEKEN.BEKEN 121 Dynamic gpon-onu_1/4/1:2 vport 2
OL01#
21. CHECKING ONT POWER
OLT-ZTE_C320#sho pon power attenuation gpon-onu_1/4/1:2
OLT ONU Attenuation
————————————————————————–
up Rx :-19.153(dbm) Tx:2.728(dbm) 21.881(dB)
down Tx :3.769(dbm) Rx:-18.890(dbm) 22.659(dB)
OLT-ZTE_C320#
22. CHECKING ONT VERSION
OLT-ZTE_C320#sho gpon remote-onu equip gpon-onu_1/4/1:2
Vendor ID: ZTEG
Version: V5.2
SN: ABCDEFGHIJ
Admin status: unlock
Battery backup: false
Security Mode: aes
Product code: 0
TotalPrioQueueNum: 64
TotalTrafficSchNum: 8
TrafficMgmtOption: priority-rate-controlled
OperState: enable
EquipID: F63.2 –> vERSION
OMCC Version: a0
Security Capability: aes
Model: F6
Survival time: N/A
TotalGemPortNum: 256
SysUpTime: 0
OLT-ZTE_C320#
23. CHECKING ONT IP (ROUTING MODE)
In This case, We used ip-host 1
in one ONT we can create 4 IP-HOST management
OLT-ZTE_C320#sho gpon remote-onu ip-host gpon-onu_1/4/1:2
Host ID: 1
HostName: omci_ipv4_dhcp_1
Identify:
IP: 0.0.0.0
Mask: 0.0.0.0
Gateway: 0.0.0.0
Primary DNS: 0.0.0.0
Second DNS: 0.0.0.0
DHCP-enable: true
Ping-response: true
Traceroute-response:true
MAC: KEREN.KEREN.KEREN
CurIP: 1.2.3.4
CurMask: 255.255.255.0
CurGateway: 1.2.3.4
CurPriDNS: 6.6.6.6
CurSecDNS: 7.7.7.7
24. CHECKING ONT PORT STATUS
OLT-ZTE_C320#sho gpon remote-onu interface eth gpon-onu_1/4/1:2
Interface: eth_0/1
Speed status: auto
Operate status:disable
Admin status: unlock –> should be unlock
Arc: 0
Arc-interval 0
Expect-type: 0
Speed config: auto
Eth-loop: disable
Max-frame: 1632
Pause-time: 0
Wiring : dce
BridgeOrIP: either
PPPOE-filter: disable
Power-control: disable
25. CHECKING ONT CONFIGURATION
OLT-ZTE_C320#sho run int gpon-onu_1/4/1:2
Building configuration…
!
interface gpon-onu_1/4/1:2
descriptionIRONMAN
tcont 1 profile share
gemport 1 name ngenet unicast tcont 1 dir both
gemport 1 traffic-limit downstream 300m
gemport 2 name nontonfelm unicast tcont 1 dir both
gemport 2 traffic-limit downstream 300m
gemport 3 name tilpun unicast tcont 1 dir both
gemport 3 traffic-limit downstream 300m
switchport mode hybrid vport 1
switchport vlan 212 tag vport 1
switchport mode hybrid vport 2
switchport vlan 121 tag vport 2
switchport mode hybrid vport 3
switchport vlan 122 tag vport 3
!
end
OLT-ZTE_C320#sho onu run con gpon-onu_1/4/1:2
pon-onu-mng gpon-onu_1/4/1:2
flow 2 switch switch_0/1
flow 3 switch switch_0/1
flow mode 1 tag-filter vid-filter untag-filter discard
flow mode 2 tag-filter vid-filter untag-filter discard
flow mode 3 tag-filter vid-filter untag-filter discard
flow 1 priority 0 vid 212
flow 2 priority 0 vid 121
flow 3 priority 0 vid 122
gemport 1 flow 1
gemport 2 flow 2
gemport 3 flow 3
switchport-bind switch_0/1 iphost 1
ip-host 1 dhcp-enable true ping-response true traceroute-response true
vlan-filter-mode iphost 1 tag-filter vid-filter untag-filter discard
vlan-filter iphost 1 priority 0 vid 212
vlan port eth_0/2 mode tag vlan 121
vlan port eth_0/3 mode tag vlan 122
dhcp-ip ethuni eth_0/2 from-internet –> bridging mode
dhcp-ip ethuni eth_0/3 from-internet –> bridging mode
!
OLT-ZTE_C320#
26. REBOOT ONT
OLT-ZTE_C320#config t
Enter configuration commands, one per line. End with CTRL/Z.
OL01(config)#pon-onu
OL01(config)#pon-onu-mng gpon-onu_1/4/1:2
OL01(gpon-onu-mng)#reboot
27. RESET FACTORY ONT
OLT-ZTE_C320#config t
Enter configuration commands, one per line. End with CTRL/Z.
OLT-ZTE_C320(config)#pon-onu
OLT-ZTE_C320(config)#pon-onu-mng gpon-onu_1/4/1:2
OLT-ZTE_C320(gpon-onu-mng)#restore factory
28. HOW TO LOCK / SHUTDOWN THIRD PORT ONT
OLT-ZTE_C320#config t
Enter configuration commands, one per line. End with CTRL/Z.
OLT-ZTE_C320(config)#pon-onu
OLT-ZTE_C320(config)#pon-onu-mng gpon-onu_1/4/1:2
OLT-ZTE_C320(gpon-onu-mng)#interface eth eth_0/3 state lock
29. HOW TO UNLOCK PORT ONT
OLT-ZTE_C320#config t
Enter configuration commands, one per line. End with CTRL/Z.
OLT-ZTE_C320(config)#pon-onu
OLT-ZTE_C320(config)#pon-onu-mng gpon-onu_1/4/1:2
OLT-ZTE_C320(gpon-onu-mng)#interface eth eth_0/3 state unlock
30. HOW TO RELEASE RENEW ONT AS DHCP CLIENT
OLT-ZTE_C320#config t
Enter configuration commands, one per line. End with CTRL/Z.
OLT-ZTE_C320(config)#pon-onu
OLT-ZTE_C320(config)#pon-onu-mng gpon-onu_1/4/1:2
OLT-ZTE_C320(gpon-onu-mng)#ip-host 1 dhcp-enable false ping-response false traceroute-response false
OLT-ZTE_C320(gpon-onu-mng)#ip-host 1 dhcp-enable true ping-response true traceroute-response true
31. CHECKING RX LEVEL FOR OLT UPLINK
Make Sure , There is no CRC Counting at your Uplink Interface :p
OLT-ZTE_C320#sho int optical-module-info xgei_1/21/1
Optical module information:xgei_1/21/1
Basic-info:
Vendor-Name : SOU Vendor-Pn : SPP1
Vendor-Sn : D9 Version-Lev : 10
Production-Date: 13 Module-Type : 10GBASE-LR
Wavelength : 1310 (nm) Connector : LC
Diagnostic-info:
RxPower : -10.1(dbm) TxPower : -1.7(dbm)
Bias-Current : 25.724 (mA) Laser-Rate : 103(100Mb/s)
Temperature : 24.184 (c) Supply-Vol : 3.324(v)
Alarm-thresh: –> Threshold
RxPower-Upper : 3 (dbm) RxPower-Lower : -34(dbm)
TxPower-Upper : 9 (dbm) TxPower-Lower : -14(dbm)
Bias-Upper : 131(mA) Bias-Lower : 0 (mA)
Voltage-Upper : 7 (v) Voltage-Lower : 0 (v)
Temperature-Upper: 90 (c) Temperature-Lower: -45(c)
OLT-ZTE_C320#
31. RESET SLOT
OLT-ZTE_C320#reset-card slotno 12
32. SWAP
Use This for First Level Handling when you get Anomaly Process.
sometimes it can help you, but sometime isn’t.
OLT-ZTE_C320#swap
33. CHECKING VLAN SUMMARY
OLT-ZTE_C320#sho vlan sum
All created vlan num: 3
Details are following:
111, 222 , 333
OLT-ZTE_C320#
OLT-ZTE_C320#sho vlan 111
vlanid :111
name :VLAN00111
description :N/A
multicast-packet:flood-unknown
tpid:0x8100
port(untagged):
port(tagged):
gpon-onu_1/2/8:128:1
xgei_1/22/1
sg1